Skip to content
CS Precast LLP logoCS Precast LLP

1500 mm Precast Manhole System

A coordinated range of precast components that supports systematic underground utility and drainage applications.

Exploded 3D view of the 1500 mm precast manhole: top slab, conical section, adjust rings, risers and bottom slab

How the system fits together

The modular combination lets the manhole be configured to project requirements. Work from the bottom up:

  1. 1Bottom SlabOD 1900 mm × 200 mm
  2. 2RiserFor 450 / 600 / 900 mm pipe
  3. 3Adjust Ring(s)150 / 300 / 600 / 1000 mm
  4. 4Top Slab / Conical Section560 mm opening

Quick reference

ComponentSizeThickness
Bottom slabOD 1900 mm200 mm
Riser (450 pipe)H 950 mm200 mm
Riser (600 pipe)H 1150 mm200 mm
Riser (900 pipe)H 1450 mm200 mm
Adjust ringsH 150 / 300 / 600 / 1000 mm125 mm
Conical sectionH 2100 mm, 1500 → 560 mm125 mm
Top slabOD 1750 mm, 560 mm opening150 mm

Assembly overview

How the components stack up

Exploded schematic of the 1500 mm precast manholeFrom bottom to top: bottom slab, riser with pipe opening, adjust ring, conical section and top slab.Top slabOD 1750 × 150 mm560 mm openingConical sectionH 2100 · 125 mm wall1500 → 560 mm dia.Adjust ring(s)Heights 150 / 300 /600 / 1000 mmRiserFor 450 / 600 / 900 mmpipe · 200 mm wallBottom slabOD 1900 × 200 mmpipe openingSchematic, not to scale
  1. 1Prepare the baseExcavate to the required level and lay a compacted, level bedding layer for the bottom slab.
  2. 2Set the bottom slabLower the slab onto the bedding and check it is level before building up.
  3. 3Stack the risersChoose risers for your pipe size (450, 600 or 900 mm) and seal each joint as specified.
  4. 4Connect the pipesFit pipes through the riser openings and make watertight connections.
  5. 5Add the adjust ringsUse rings of 150–1000 mm to bring the manhole exactly to the final ground or road level.
  6. 6Finish the topPlace the top slab or conical section, seal the joints and fit the frame and cover.

General guidance only. Always follow your project specification, drawings and site engineer's instructions.

Manhole component range: top slab, conical section and modular configuration with dimensions

Top slab, conical section and modular configuration

Finish the assembly with a 1750 mm top slab, or use the 2100 mm conical section that tapers from 1500 mm to the 560 mm access opening. Adjust rings in between set the final level.

Need precast manhole components for your project?

Share your quantities and pipe sizes and we will get back to you. Call +91 98257 80565.